LOTUS High Pressure reducer (HPRV) are typically used in SWAS to reduce pressure from approx 300 bar to approx 10 bar
This type of pressure reducer are recommended as per ASME PTC 19.11-2008 & D1192 standard for boiler sampling lines having pressure above 35 bar.

Features
 Designed as per ASME PTC 19.11-2008 & D1192 standard guidelines
 HPRV uses Rod-in-tube design for seamless pressure reduction with minimal wear & tear of parts
 HPRV allows precise control of flow and pressure without valve erosion or fluid dissociation
 HPRV can be cleaned of dirt or corrosion products without shutting down the sample stream.
 Designed and rated for High pressure upto 5000 psig (345 bar) at 149 deg.C
 Outlet pressure adjustable from 1 to 20 barg
 All Wetted parts in SS316